# User Manual Ahoy DTU (on ESP8266)
|
||
2 years ago
|
Version #{VERSION}#
|
||
2 years ago
|
## Introduction
|
||
2 years ago
|
See the repository [README.md](Getting_Started.md)
|
||
2 years ago
|
|
||
|
## Setup
|
||
2 years ago
|
Assuming you have a running ahoy-dtu and you can access the setup page.
|
||
|
In the initial case or after click "erase settings" the fields for the inverter setup are empty.
|
||
2 years ago
|
|
||
2 years ago
|
Set at least the serial number and a name for each inverter, check "reboot after save" and click the "Save" button.
|
||
2 years ago
|
|
||
2 years ago
|
## MQTT Output
|
||
|
The ahoy dtu will publish on the following topics
|
||
2 years ago
|
`<CHOOSEN_TOPIC_FROM_SETUP>/<INVERTER_NAME_FROM_SETUP>/ch0/#`
|
||
|
|
||
2 years ago
|
| Topic | Example Value | Remarks |
|
||
|
|---|---|---|
|
||
|
|U_AC | 233.300|actual AC Voltage in Volt|
|
||
|
|I_AC | 0.300 | actual AC Current in Ampere|
|
||
|
|P_AC | 71.000| actual AC Power in Watt|
|
||
2 years ago
|
|Q_AC | 21.200| actual AC reactive power in var|
|
||
2 years ago
|
|F_AC | 49.990| actual AC Frequency in Hz|
|
||
|
|PF_AC | 95.800| actual AC Power factor|
|
||
2 years ago
|
|Temp | 19.800|Temperature of inverter in Celsius|
|
||
2 years ago
|
|EVT | 9.000|Last Event/Alarm Message Index|
|
||
2 years ago
|
|YieldDay | 51.000|Energy converted to AC per day in Watt hours (measured on DC)|
|
||
|
|YieldTotal | 465.294|Energy converted to AC since reset Watt hours (measured on DC)|
|
||
|
|P_DC | 74.600|actual DC Power in Watt|
|
||
|
|Efficiency | 95.174|actual ration AC Power over DC Power in percent|
|
||
|
|FWVersion | 10012.000| Firmware version eg. 1.00.12|
|
||
|
|FWBuildYear | 2020.000| Firmware build date|
|
||
|
|FWBuildMonthDay | 624.000| Firmware build month and day eg. 24th of june|
|
||
|
|HWPartId | 100.000| Hardware Id|
|
||
|
|PowerLimit | 80.000|actual set point for power limit control AC active power in percent|
|
||
|
|LastAlarmCode | 1.000| Last Alarm Code eg. "inverter start"|
|
||
|
|
||
2 years ago
|
`<CHOOSEN_TOPIC_FROM_SETUP>/<INVERTER_NAME_FROM_SETUP>/ch<CHANNEL_NUMBER>/#`
|
||
|
|
||
|
`<CHANNEL_NUMBER>` is in the range 1 to 4 depending on the inverter type
|
||
2 years ago
|
|
||
|
| Topic | Example Value | Remarks |
|
||
|
|---|---|---|
|
||
|
|U_DC | 38.900| actual DC Voltage in Volt|
|
||
|
|I_DC | 0.640 | actual DC current in Ampere|
|
||
|
|P_DC | 25.000 | actual DC power in Watt|
|
||
|
|YieldDay | 17.000 | Energy converted to AC per day Watt hours per module/channel (measured on DC) |
|
||
|
|YieldTotal | 110.819 | Energy converted to AC since reset Watt hours per module/channel (measured on DC) |
|
||
2 years ago
|
|Irradiation |5.65 | ratio DC Power over set maximum power per module/channel in percent |
|
||
2 years ago
|
|
||
2 years ago
|
## Active Power Limit via Setup Page
|
||
2 years ago
|
If you leave the field "Active Power Limit" empty during the setup and reboot the ahoy-dtu will set a value of 65535 in the setup.
|
||
2 years ago
|
That is the value you have to fill in case you want to operate the inverter without a active power limit.
|
||
|
If the value is 65535 or -1 after another reboot the value will be set automatically to "100" and in the drop-down menu "relative in percent persistent" will be set. Of course you can do this also by your self.
|
||
2 years ago
|
|
||
|
You can change the setting in the following manner.
|
||
|
Decide if you want to set
|
||
2 years ago
|
|
||
2 years ago
|
- an absolute value in Watt
|
||
|
- an relative value in percent based on the maximum Power capabilities of the inverter
|
||
2 years ago
|
|
||
2 years ago
|
and if this settings shall be
|
||
2 years ago
|
|
||
2 years ago
|
- persistent
|
||
|
- not persistent
|
||
2 years ago
|
|
||
2 years ago
|
after a power cycle of the inverter (P_DC=0 and P_AC=0 for at least 10 seconds)
|
||
2 years ago
|
|
||
2 years ago
|
The user has to ensure correct settings. Remember that for the inverters of 3rd generation the relative active power limit is in the range of 2% up to 100%.
|
||
2 years ago
|
Also an absolute active power limit below approx. 30 Watt seems to be not meanful because of the control capabilities and reactive power load.
|
||
2 years ago
|
|
||
|
## Active Power Limit via MQTT
|
||
2 years ago
|
The ahoy-dtu subscribes on the topic `<CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/#` if the mqtt broker is set-up correctly. The default topic is `inverter/devcontrol/#`.
|
||
2 years ago
|
|
||
2 years ago
|
To set the active power limit (controled value is the AC Power of the inverter) you have four options. (Only single phase inverters are actually in focus).
|
||
2 years ago
|
|
||
2 years ago
|
| topic | payload | active power limit in | Condition |
|
||
|
| --------------------------------------------------------------- | ----------- | -------------------------------------------- | -------------- |
|
||
2 years ago
|
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11 OR <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/0 | [0..65535] | Watt | not persistent |
|
||
|
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/256 | [0..65535] | Watt | persistent |
|
||
|
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/1 | [2..100] | % | not persistent |
|
||
|
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/257 | [2..100] | % | persistent |
|
||
2 years ago
|
|
||
2 years ago
|
👆 `<INVERTER_ID>` is the number of the specific inverter in the setup page.
|
||
2 years ago
|
|
||
2 years ago
|
* First inverter --> `<INVERTER_ID>` = 0
|
||
|
* Second inverter --> `<INVERTER_ID>` = 1
|
||
2 years ago
|
* ...
|
||
|
|
||
2 years ago
|
### Developer Information MQTT Interface
|
||
2 years ago
|
`<CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/<DevControlCmdType>/<DATA2>`
|
||
2 years ago
|
|
||
2 years ago
|
The implementation allows to set any of the available `<DevControlCmdType>` Commands:
|
||
2 years ago
|
```C
|
||
2 years ago
|
typedef enum {
|
||
2 years ago
|
TurnOn = 0, // 0x00
|
||
|
TurnOff = 1, // 0x01
|
||
|
Restart = 2, // 0x02
|
||
|
Lock = 3, // 0x03
|
||
|
Unlock = 4, // 0x04
|
||
|
ActivePowerContr = 11, // 0x0b
|
||
|
ReactivePowerContr = 12, // 0x0c
|
||
|
PFSet = 13, // 0x0d
|
||
2 years ago
|
CleanState_LockAndAlarm = 20, // 0x14
|
||
2 years ago
|
SelfInspection = 40, // 0x28, self-inspection of grid-connected protection files
|
||
|
Init = 0xff
|
||
2 years ago
|
} DevControlCmdType;
|
||
|
```
|
||
2 years ago
|
The MQTT payload will be set on first to bytes and `<DATA2>`, which is taken from the topic path will be set on the second two bytes if the corresponding DevControlCmdType supports 4 byte data.
|
||
2 years ago
|
See here the actual implementation to set the send buffer bytes.
|
||
|
```C
|
||
2 years ago
|
void sendControlPacket(uint64_t invId, uint8_t cmd, uint16_t *data) {
|
||
|
sendCmdPacket(invId, TX_REQ_DEVCONTROL, ALL_FRAMES, false);
|
||
|
int cnt = 0;
|
||
|
// cmd --> 0x0b => Type_ActivePowerContr, 0 on, 1 off, 2 restart, 12 reactive power, 13 power factor
|
||
|
mTxBuf[10] = cmd;
|
||
|
mTxBuf[10 + (++cnt)] = 0x00;
|
||
|
if (cmd >= ActivePowerContr && cmd <= PFSet){
|
||
|
mTxBuf[10 + (++cnt)] = ((data[0] * 10) >> 8) & 0xff; // power limit || high byte from MQTT payload
|
||
|
mTxBuf[10 + (++cnt)] = ((data[0] * 10) ) & 0xff; // power limit || low byte from MQTT payload
|
||
|
mTxBuf[10 + (++cnt)] = ((data[1] ) >> 8) & 0xff; // high byte from MQTT topic value <DATA2>
|
||
|
mTxBuf[10 + (++cnt)] = ((data[1] ) ) & 0xff; // low byte from MQTT topic value <DATA2>
|
||
|
}
|
||
|
// crc control data
|
||
|
uint16_t crc = Hoymiles::crc16(&mTxBuf[10], cnt+1);
|
||
|
mTxBuf[10 + (++cnt)] = (crc >> 8) & 0xff;
|
||
|
mTxBuf[10 + (++cnt)] = (crc ) & 0xff;
|
||
|
// crc over all
|
||
|
cnt +=1;
|
||
|
mTxBuf[10 + cnt] = Hoymiles::crc8(mTxBuf, 10 + cnt);
|
||
|
|
||
|
sendPacket(invId, mTxBuf, 10 + (++cnt), true);
|
||
|
}
|
||
2 years ago
|
```
|
||
2 years ago
|
|
||
2 years ago
|
So as example sending any payload on `inverter/devcontrol/0/1` will switch off the inverter.
|
||
2 years ago
|
|
||
2 years ago
|
## Active Power Limit via REST API
|
||
|
It is also implemented to set the power limit via REST API call. Therefore send a POST request to the endpoint /api.
|
||
|
The response will always be a json with {success:true}
|
||
|
The payload shall be a json formated string in the following manner
|
||
|
```json
|
||
|
{
|
||
|
"inverter":<INVERTER_ID>,
|
||
|
"tx_request": <TX_REQUEST_BYTE>,
|
||
|
"cmd": <SUB_CMD_BYTE>,
|
||
|
"payload": <PAYLOAD_INTEGER_TWO_BYTES>,
|
||
|
"payload2": <PAYLOAD_INTEGER_TWO_BYTES>
|
||
|
}
|
||
|
```
|
||
|
With the following value ranges
|
||
2 years ago
|
|
||
2 years ago
|
|
||
|
| Value | range | note |
|
||
|
| --------------------------- | ----------- | ------------------------------- |
|
||
|
| <TX_REQUEST_BYTE> | 81 or 21 | integer uint8, (0x15 or 0x51) |
|
||
|
| <SUB_CMD_BYTE> | [0...255] | integer uint8, subcmds eg. 0x0b |
|
||
|
| <PAYLOAD_INTEGER_TWO_BYTES> | [0...65535] | uint16 |
|
||
|
| <INVERTER_ID> | [0...3] | integer uint8 |
|
||
2 years ago
|
|
||
2 years ago
|
Example to set the active power limit non persistent to 10%
|
||
|
```json
|
||
|
{
|
||
|
"inverter":0,
|
||
|
"tx_request": 81,
|
||
|
"cmd": 11,
|
||
|
"payload": 10,
|
||
|
"payload2": 1
|
||
|
}
|
||
|
```
|
||
|
Example to set the active power limit persistent to 600Watt
|
||
|
```json
|
||
|
{
|
||
|
"inverter":0,
|
||
|
"tx_request": 81,
|
||
|
"cmd": 11,
|
||
|
"payload": 600,
|
||
|
"payload2": 256
|
||
|
}
|
||
|
```
|
||
2 years ago
|
|
||
2 years ago
|
### Developer Information REST API
|
||
2 years ago
|
In the same approach as for MQTT any other SubCmd and also MainCmd can be applied and the response payload can be observed in the serial logs. Eg. request the Alarm-Data from the Alarm-Index 5 from inverter 0 will look like this:
|
||
|
```json
|
||
|
{
|
||
|
"inverter":0,
|
||
|
"tx_request": 21,
|
||
|
"cmd": 17,
|
||
|
"payload": 5,
|
||
|
"payload2": 0
|
||
|
}
|
||
|
```
|
||
2 years ago
|
|
||
2 years ago
|
## Zero Export Control
|
||
2 years ago
|
* You can use the mqtt topic `<CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11` with a number as payload (eg. 300 -> 300 Watt) to set the power limit to the published number in Watt. (In regular cases the inverter will use the new set point within one intervall period; to verify this see next bullet)
|
||
|
* You can check the inverter set point for the power limit control on the topic `<CHOOSEN_TOPIC_FROM_SETUP>/<INVERTER_NAME_FROM_SETUP>/ch0/PowerLimit` 👆 This value is ALWAYS in percent of the maximum power limit of the inverter. In regular cases this value will be updated within approx. 15 seconds. (depends on request intervall)
|
||
|
* You can monitor the actual AC power by subscribing to the topic `<CHOOSEN_TOPIC_FROM_SETUP>/<INVERTER_NAME_FROM_SETUP>/ch0/P_AC` 👆 This value is ALWAYS in Watt
|
||
2 years ago
|
|
||
|
## Issues and Debuging for active power limit settings
|
||
2 years ago
|
|
||
2 years ago
|
Turn on the serial debugging in the setup. Try to have find out if the behavior is deterministic. That means can you reproduce the behavior. Be patient and wait on inverter reactions at least some minutes and beware that the DC-Power is sufficient.
|
||
2 years ago
|
|
||
2 years ago
|
In case of issues please report:
|
||
2 years ago
|
|
||
2 years ago
|
1. Version of firmware
|
||
|
2. The output of the serial debug esp. the TX messages starting with "0x51" and the RX messages starting with "0xD1" or "0xF1"
|
||
|
3. Which case you have tried: Setup-Page, MQTT, REST API and at what was shown on the "Visualization Page" at the Location "Limit"
|
||
2 years ago
|
4. The setting means payload, relative, absolute, persistent, not persistent (see tables above)
|
||
|
|
||
2 years ago
|
**Developer Information General for Active Power Limit**
|
||
2 years ago
|
|
||
|
⚡The following was verified by field tests and feedback from users
|
||
|
|
||
2 years ago
|
Internally this values will be set for the second two bytes for MainCmd: 0x51 SubCmd: 0x0b --> DevControl set ActivePowerLimit
|
||
2 years ago
|
```C
|
||
2 years ago
|
typedef enum {
|
||
|
AbsolutNonPersistent = 0x0000, // 0
|
||
|
RelativNonPersistent = 0x0001, // 1
|
||
2 years ago
|
AbsolutPersistent = 0x0100, // 256
|
||
|
RelativPersistent = 0x0101 // 257
|
||
2 years ago
|
} PowerLimitControlType;
|
||
2 years ago
|
```
|
||
2 years ago
|
|
||
2 years ago
|
## Firmware Version collection
|
||
|
Gather user inverter information here to understand what differs between some inverters.
|
||
|
|
||
2 years ago
|
| Name | Inverter Typ | Bootloader V. | FWVersion | FWBuild [YYYY] | FWBuild [MM-DD] | HWPartId | | |
|
||
|
| ---------- | ------------ | ------------- | --------- | -------------- | --------------- | --------- | -------- | --------- |
|
||
|
| DanielR92 | HM-1500 | | 1.0.16 | 2021 | 10-12 | 100 | | |
|
||
|
| isdor | HM-300 | | 1.0.14 | 2021 | 12-09 | 102 | | |
|
||
|
| aschiffler | HM-1500 | | 1.0.12 | 2020 | 06-24 | 100 | | |
|
||
|
| klahus1 | HM-300 | | 1.0.10 | 2020 | 07-07 | 102 | | |
|
||
2 years ago
|
| roku133 | HM-400 | | 1.0.10 | 2020 | 07-07 | 102 | | |
|
||
2 years ago
|
| eeprom23 | HM-1200 | 0.1.0 | 1.0.18 | 2021 | 12-24 | 269619201 | 18:21:00 | HWRev 256 |
|
||
|
| eeprom23 | HM-1200 2t | 0.1.0 | 1.0.16 | 2021 | 10-12 | 269619207 | 17:06:00 | HWRev 256 |
|
||
|
| fila612 | HM-700 | | 1.0.10 | 2021 | 11-01 | 104 | | |
|
||
2 years ago
|
| tfhcm | TSUN-350 | | 1.0.14 | 2021 | 12-09 | 102 | | |
|
||
2 years ago
|
| Groobi | TSOL-M400 | | 1.0.14 | 2021 | 12-09 | 102 | | |
|
||
2 years ago
|
| setje | HM-600 | | 1.0.08 | 2020 | 07-10 | 104 | | |
|
||
2 years ago
|
| madmartin | HM-600 | 0.1.4 | 1.0.10 | 2021 | 11-01 | 104 | | |
|
||
2 years ago
|
| lumapu | HM-1200 | 0.1.0 | 1.0.12 | 2020 | 06-24 | | | |
|
||
2 years ago
|
| chehrlic | HM-600 | | 1.0.10 | 2021 | 11-01 | 104 | | |
|
||
|
| chehrlic | TSOL-M800de | | 1.0.10 | 2021 | 11-01 | 104 | | |
|
||
2 years ago
|
| B5r1oJ0A9G | HM-800 | | 1.0.10 | 2021 | | 104 | | |
|
||
2 years ago
|
| | | | | | | | | |
|
||
|
| | | | | | | | | |
|
||
2 years ago
|
|
||
|
## Developer Information about Command Queue
|
||
|
After reboot or startup the ahoy firmware it will enque three commands in the following sequence:
|
||
|
|
||
2 years ago
|
1. Get active power limit in percent (`SystemConfigPara = 5 // 0x05`)
|
||
|
2. Get firmware version (`InverterDevInform_All = 1 // 0x01`)
|
||
|
3. Get data (`RealTimeRunData_Debug = 11 // 0x0b`)
|
||
|
|
||
|
With the command get data (`RealTimeRunData_Debug = 11 // 0x0b`) the alarm message counter will be updated. In the initial case then aonther command is queued to get the alarm code (`AlarmData = 17 // 0x11`).
|
||
2 years ago
|
|
||
2 years ago
|
This command (`AlarmData = 17 // 0x11`) will enqued in any operation phase if alarm message counter is raised by one or greater compared to the last request with command get data (`RealTimeRunData_Debug = 11 // 0x0b`)
|
||
2 years ago
|
|
||
2 years ago
|
In case all commands are processed (`_commandQueue.empty() == true`) then as a default command the get data (`RealTimeRunData_Debug = 11 // 0x0b`) will be enqueued.
|
||
2 years ago
|
|
||
|
In case a Device Control command (Power Limit, Off, On) is requested via MQTT or REST API this request will be send before any other enqueued command.
|
||
2 years ago
|
In case of a accepted change in power limit the command get active power limit in percent (`SystemConfigPara = 5 // 0x05`) will be enqueued. The acceptance is checked by the reponse packets on the devive control commands (tx id 0x51 --> rx id 0xD1) if in byte 12 the requested sub-command (eg. power limit) is present.
|
||
2 years ago
|
|
||
|
## How To
|
||
|
### Sunrise & Sunset
|
||
|
In order to display the sunrise and sunset on the start page, the location coordinates (latitude and longitude) must be set in decimal in the setup under Sunrise & Sunset. If the coordinates are set, the current sunrise and sunset are calculated and displayed daily.
|
||
|
If this is set, you can also tick "disable night communication", then sending to the inverter is switched off outside of the day (i.e. at night), this avoids unnecessary communication attempts and thus also the incrementing of "RX no anwser".
|
||
|
Here you can get easy your GeoLocation: [https://www.mapsdirections.info/en/gps-coordinates.html](https://www.mapsdirections.info/en/gps-coordinates.html)
|
||
|
### Commands and informations
|
||
|
Turn On - turns on the inverter/feeder (LED flashes green if there is no error)
|
||
|
Turn Off - switches off the inverter/feeder (LED flashes fast red), can be switched on again with Turn On or by disconnecting and reconnecting the DC voltage
|
||
|
Restart - restarts the microcontroller in the inverter, which deletes the error memory and the YieldDay values, feed-in stops briefly and starts with the last persistent limit
|
||
|
Send Power Limit:
|
||
|
- A limitation of the AC power can be sent in relative (in %) or in absolute (Watt).
|
||
|
- It can be set to a different value non-persistently (temporarily) at any time (regardless of what you have set for persistent), this should be normal in order to limit the power (zero feed/battery control) and does not damage the EEPROM in the WR either.
|
||
|
- With persistent you send a saving limit (only use it seldom, otherwise the EEPROM in the HM can break!), This is then used as the next switch-on limit when DC comes on, i.e. when the sun comes up early or the WR on batteries is switched on the limit is applied immediately when sending, like any other, but it is stored in the EEPROM of the WR.
|
||
|
- A persistent limit is only needed if you want to throttle your inverter permanently or you can use it to set a start value on the battery, which is then always the switch-on limit when switching on, otherwise it would ramp up to 100% without regulation, which is continuous load is not healthy.
|
||
|
- You can set a new limit in the turn-off state, which is then used for on (switching on again), otherwise the last limit from before the turn-off is used, but of course this only applies if DC voltage is applied the whole time.
|
||
|
- If the DC voltage is missing for a few seconds, the microcontroller in the inverter goes off and forgets everything that was temporary/non-persistent in the RAM: YieldDay, error memory, non-persistent limit.
|