  1. 151
      doc/hoymiles-format-description.txt

151
doc/hoymiles-format-description.txt

@ -1,11 +1,11 @@
Goal of this Document
=====================
About this Document
===================
This description aims to document the data format that Hoymiles
micro inverters use to communicate their current operating state.
The original Hoymiles setup requires connectivity to "the cloud",
see [this chapter](#system-description).
see [this section below](#system-description).
With the information documented here, it is possible to interact with
a set of Hoymiles micro inverters in a purely "offline" way, i.e.
@ -13,11 +13,11 @@ without requiring internet access or any connectivity to a "cloud".
The only required hardware is a Nordic "NRF24L01+" wireless module.
The `ahoy` project at [ahoy] collects software for various platforms,
The `ahoy` project at [5] collects software for various platforms,
including Aduino and RaspberryPi.
> Note: Some of the sections in this document are (still) in German. Translation
> will be provided if and when necessary.
> Note: Some of the sections in this document are (still) in German. Translations
> may be provided if and when necessary.
Origin, Contributors
@ -44,7 +44,7 @@ Here's a list of some of the early contributors:
- Thomas B. (tbnobody): protocol analysis, logging
- Arnaldo G. (arnaldo_g): data capturing
- Oliver F (of22): protocol analysis, logging
- Martin G. (petersilie): protocol analysis, logging
- Martin G. (petersilie): protocol analysis, logging, RaspberryPi
@ -56,7 +56,8 @@ Ein Setup wie von Hoymiles vorgesehen, sieht wie folgt aus:
- Eine "DTU" kommuniziert mit vielen Wechselrichtern.
- Die Kommunikation geht immer von der DTU aus:
DTU stellt Anfrage und erwartet eine Antwort vom WR.
- Dafür muss die DTU die Adressen aller WR kennen.
- Dafür muss die DTU die Adressen (=Seriennummern) aller WR kennen.
- Diese werden der DTU im Rahmen eines Einrichtungsprozesses beigebracht.
```
Nordic
@ -67,20 +68,20 @@ Ein Setup wie von Hoymiles vorgesehen, sieht wie folgt aus:
+-------+ +-----------+
| DTU | | MI-600 |
+-------+ +-----------+-+
| MI-600 |
| MI-1500 |
+-----------+-+
| MI-1500 |
| MI-... |
+-----------+
:
:
:
:
ABBILDUNG 1: Systemübersicht
```
```
Nordic
WLAN "Enh. Shockburst"
2.4 GHz
Nordic
WLAN "Enh. Shockburst"
2.4 GHz
\|/ \|/
| |
+---------+ +-----------+
@ -97,9 +98,9 @@ Ein Setup wie von Hoymiles vorgesehen, sieht wie folgt aus:
```
Nordic
"Enh. Shockburst"
NRF24LE1E 2.4 GHz
Nordic
"Enh. Shockburst"
NRF24LE1E 2.4 GHz
+------------------+ \|/
+----------+ | | | |
| GD32F303 | <----->| µC | NRF24L01+ |-------+
@ -114,7 +115,7 @@ Ein Setup wie von Hoymiles vorgesehen, sieht wie folgt aus:
Adressierung
============
Die Seriennummern der DTU und der WR werden wie folgt in Adressen für die
Die Seriennummern der DTU und der WR werden wie folgt als Adressen für die
Kommunikation verwendet:
**Interne Kommunikation**: Die meisten Datenpakete enthalten Quell- und
@ -129,7 +130,7 @@ Innerhalb der Pakete auf (C) wird daraus die 4-Byte-Adresse
der letzen 8 Dezimalziffern.
**NRF24 addressing scheme**: Over the air, the inverters communicate using
the Nordic "Enhanced Shockburst" [3] Protocol configured for
the [Nordic "Enhanced Shockburst" Protocol][3] configured for
5-byte addresses.
The inverter serial number is converted into a "Shockburst" address
@ -147,9 +148,10 @@ In this example, the resulting "Shockburst" address is: 0x3288817201.
**Additional example**, this time for inverter with serial number 99973104619:
The datasheet specifies the over-the-air packet format: "Most Significant Byte
(MSB) to the left" (cf figure 11)
(MSB) to the left" (cf [datasheet figure 11][3])
Address := Byte_4, Byte_3, Byte_2, Byte_1, Byte_0 ("LSByte must be unique")
Address := Byte_4, Byte_3, Byte_2, Byte_1, Byte_0
("LSByte must be unique")
so 0x1946107301 results in
@ -201,12 +203,12 @@ and some translation/mangling/processing happens inside the NRF24LE1E, in partic
- recalculation of CRCs
These packets (which are all framed in 0x7e...0x7f bytes) are described in section
"encapsulated packets" below.
[Encapsulated Packets](#encapsulated-packets) below.
More recent efforts focus mainly on the actual "Enhanced Shockburst" packets
that are transmitted over the air. These packets are described in section
"Enhanced Shockburst Payloads", and the information contained in this section is
more up to date.
[Enhanced Shockburst Payloads](#Enhanced-Shockburst-Payloads), and the
information contained in this section is more up to date.
@ -217,17 +219,19 @@ Encapsulated Packets
These are packets as observed on Link (C) in figure (3).
Nachricht: DTU an WR: "Init" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
7E 07 00 00 00 00 00 00 00 00 00 07 7F
^^ ^^ ^^^^^^^^^^^ ^^^^^^^^^^^ ^^ ^^
Bedeutung SOF MID WR ser# WR ser# ? CRC8 EOF
```
?
Nachricht: DTU an WR: "Init 2" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
7E 07 72 81 88 32 72 81 88 32 00 07 7F
@ -235,10 +239,12 @@ Nachricht: DTU an WR: "Init 2" (?)
Bedeutung SOF MID DTU ser# DTU ser# ? CRC8 EOF
Einheit BCD (letzte 8) BCD (letzte 8) ? ?
Beispiel 72818832 72818832 ?
```
Nachricht 0x80: DTU an WR: "Zeit setzen" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
|<-------------CRC16 'modbus' für CRC_M----------------->|
7E 15 72 22 02 00 72 22 02 00 80 0B 00 62 09 04 9b 00 00 00 00 00 00 00 00 F2 68 F0 7F
@ -246,10 +252,12 @@ Nachricht 0x80: DTU an WR: "Zeit setzen" (?)
Bedeutung SOF MID WR ser# WR ser# CMD ? TIME (UTC) CRC_M CRC8 EOF
Einheit BCD (letzte 8) BCD (letzte 8) ? [s] HI LO
Beispiel 72220200 72220200 ? 2022-02-13
```
13:16:11
Nachricht 0x81: DTU an WR: "Anfrage DC-Daten" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
GD->NRF 7E 15 70 51 43 68 70 51 43 68 81 xx 7F ...... (NOCH NICHT VERIFIZIERT / GESEHEN)
@ -261,9 +269,11 @@ GD->NRF 7E 15 70 51 43 68 70 51 43 68 81 xx 7F ..
on-air 15 70 51 43 68 70 53 54 53 81 BA
(payload) ^^^^^^^^^^^ ^^^^^^^^^^^
WR ser # DTU ser #
```
Nachricht 0x82: DTU an WR: "Anfrage AC-Daten" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
GD->NRF 7E 15 70 51 43 68 70 51 43 68 82 xx 7F ...... (NOCH NICHT VERIFIZIERT / GESEHEN)
@ -275,9 +285,11 @@ GD->NRF 7E 15 70 51 43 68 70 51 43 68 82 xx 7F ..
on-air 15 70 51 43 68 70 53 54 53 82 B9
(payload) ^^^^^^^^^^^ ^^^^^^^^^^^
WR ser # DTU ser #
```
Nachricht 0x83: DTU an WR: "Anfrage DC-Daten" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
GD->NRF 7E 15 70 51 43 68 70 51 43 68 83 xx 7F ...... (NOCH NICHT VERIFIZIERT / GESEHEN)
@ -289,9 +301,11 @@ GD->NRF 7E 15 70 51 43 68 70 51 43 68 83 xx 7F ..
on-air 15 70 51 43 68 70 53 54 53 83 B8
(payload) ^^^^^^^^^^^ ^^^^^^^^^^^
WR ser # DTU ser #
```
Nachricht 0x85: DTU an WR: "???" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
GD->NRF 7E 15 70 51 43 68 70 51 43 68 85 xx 7F ...... (NOCH NICHT VERIFIZIERT / GESEHEN)
@ -303,9 +317,11 @@ GD->NRF 7E 15 70 51 43 68 70 51 43 68 85 xx 7F ..
on-air 15 70 51 43 68 70 53 54 53 85 BE
(payload) ^^^^^^^^^^^ ^^^^^^^^^^^
WR ser # DTU ser #
```
Nachricht 0xFF: DTU an WR: "???" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
GD->NRF 7E 15 70 51 43 68 70 51 43 68 FF xx 7F ...... (NOCH NICHT VERIFIZIERT / GESEHEN)
@ -317,9 +333,11 @@ GD->NRF 7E 15 70 51 43 68 70 51 43 68 FF xx 7F ..
on-air 15 70 51 43 68 70 53 54 53 FF C4
(payload) ^^^^^^^^^^^ ^^^^^^^^^^^
WR ser # DTU ser #
```
Nachricht 0x01: WR an DTU: "Aktuelle DC Daten" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
7E 95 72 22 02 00 72 22 02 00 01 00 01 01 4c 03 bd 0c 46 00 b5 00 03 00 05 00 00 BD 7F
@ -327,9 +345,11 @@ Nachricht 0x01: WR an DTU: "Aktuelle DC Daten" (?)
Bedeutung SOF MID WR ser# WR ser# CMD ? PV1.u PV1.i PV1.p PV2.u PV2.i PV2.p ? CRC8 EOF
Einheit BCD (letzte 8) BCD (letzte 8) ? [0.1V] [0.01A] [.1W] [0.1V] [0.01A] [.1W] ?
Beispiel 72220200 72220200 ? 33.2V 9.57A 317.2W 18.1V 0.03A 0.5W ?
```
Nachricht 0x02: WR an DTU: "Aktuelle AC Daten" (?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
7E 95 72 22 02 00 72 22 02 00 02 28 23 00 00 24 44 00 3C 00 00 09 0F 13 88 0B D5 83 7F
@ -337,9 +357,11 @@ Nachricht 0x02: WR an DTU: "Aktuelle AC Daten" (?)
Bedeutung SOF MID WR ser# WR ser# CMD ? ? ? AC.u AC.f AC.p CRC8 EOF
Einheit BCD (letzte 8) BCD (letzte 8) ? [0.1V] [0.01Hz] [0.1W]
Beispiel 72220200 72220200 ? 9284 60 231.9V 50.00Hz 302.9W
```
Nachricht 0x83: WR an DTU (?): "???" (nach CMD wäre das eher auch eine Antwort vom WR?)
```
----------------------------------------------------------------------------------------------------------------------------------------------
7E 95 72 22 02 00 72 22 02 00 83 00 03 00 83 03 E8 00 B2 00 0A FD 26 1E 7F
@ -347,6 +369,7 @@ Nachricht 0x83: WR an DTU (?): "???" (nach CMD wäre das eher auch eine Antwort
Bedeutung SOF MID WR ser# WR ser# CMD ? ? ? ? ? ? CRC8 EOF
Einheit BCD (letzte 8) BCD (letzte 8) ?
Beispiel 72220200 72220200 ? 131 1000 178 10
```
@ -368,7 +391,7 @@ Enhanced Shockburst Payloads
- These are the packets that are exchanged between inverters and DTU via the Nordic
"Enhanced Shockburst" protocol.
- Each payload is preceded by a preamble, and terminated by a 16-bit CRC, as described
in the corresponding Nordic datasheet. See also figure 4 above.
in the [Nordic datasheet][3]. See also figure 4 above.
@ -378,17 +401,20 @@ CMD 0x80: DTU --> WR: "Set time/date" (?)
|<-------------CRC16 'modbus' für CRC_M----------------->|
15 72220200 72220200 80 0B 00 62 09 04 9b 00 00 00 00 00 00 00 00 F2 68 F0
^^ ^^^^^^^^ ^^^^^^^^ ^^ ^^^^^ ^^^^^^^^^^^ ^^^^^ ^^^^^ ^^
Name MID DST_SER# SRC_SER# CMD uk1 TIME (local) SEQ? CRC_M CRC8
Name MID DTU_SER# DTU_SER# CMD uk1 TIME (local) SEQ? CRC_M CRC8
Units see "addressing" ? [s-since-epoch] HI LO
Example 72220200 72220200 ? 2022-02-13
13:16:11
```
- This message will cause the inverter to transmit a CMD=0x01, CMD=0x02, and, occasionally, also a CMD=0x83 message
to the DTU with serial number DST_SER#.
to the DTU with serial number DTU_SER#.
- Values of "0xb0, 0x00" and "0x11, 0x00" have been observed for "UK1". Their meaning is unknown.
- "SEQ" was observed to contain increasing numbers when sent by a Hoymiles DTU. In particular,
each issued "command" (e.g. "switch inverter on", "switch inverter off") appears to increase this
value. A constant value of 0x0000 or 0x0005 appears to work just fine.
- Repeatedly sending the same TIME information (instead of correctly increasing time)
[has been shown](https://www.mikrocontroller.net/topic/525778?page=2#7021386) to result
in identical behaviour, the inverter still replies as described above.
```
@ -404,7 +430,9 @@ Example 72220200 72220200 ? 33.2V 9.57A
- The exact meaning of the contents of this message varies depending on inverter type. So far, the following variants have been observed:
- HM-400 (single channel):
- HM-700 (2-channel):
- HM-1500 (4-channel):
- HM-1500 (4-channel):
```
TODO TODO TODO
73109025 73109025 01 00 01 014F 0003 000B 0000 40AE 03AC 08E6 7C
^^^^ ^^^^ ^^^^ ^^^^ ^^^^
335 3 11 940 2278
@ -414,14 +442,16 @@ Example 72220200 72220200 ? 33.2V 9.57A
^^^^ ^^^^ ^^^^ ^^^^ ^^^^
349 77 179 1 13337
34.9V 0.77A 1.79W 1 133.37kW
```
```
Nachricht 0x02: WR an DTU: "Aktuelle AC Daten" (?)
----------------------------------------------------------------------------------------------------------------------------------------------
7E 95 72 22 02 00 72 22 02 00 02 28 23 00 00 24 44 00 3C 00 00 09 0F 13 88 0B D5 83 7F
^^ ^^ ^^^^^^^^^^^ ^^^^^^^^^^^ ^^ ^^^^^ ^^^^^ ^^^^^ ^^ ^^
Bedeutung SOF MID WR ser# WR ser# CMD ? ? ? AC.u AC.f AC.p CRC8 EOF
7E 95 72 22 02 00 72 22 02 00 02 28 23 00 00 24 44 00 3C 00 00 09 0F 13 88 0B D5 83
^^ ^^ ^^^^^^^^^^^ ^^^^^^^^^^^ ^^ ^^^^^ ^^^^^ ^^^^^ ^^
Bedeutung SOF MID WR ser# WR ser# CMD ? ? ? AC.u AC.f AC.p CRC8
Einheit BCD (letzte 8) BCD (letzte 8) ? [0.1V] [0.01Hz] [0.1W]
Beispiel 72220200 72220200 ? 9284 60 231.9V 50.00Hz 302.9W
```
@ -432,23 +462,25 @@ Beispiel 72220200 72220200 ? 9
Nachricht 0x83: WR an DTU (?): "???" (nach CMD wäre das eher auch eine Antwort vom WR?)
----------------------------------------------------------------------------------------------------------------------------------------------
7E 95 72 22 02 00 72 22 02 00 83 00 03 00 83 03 E8 00 B2 00 0A FD 26 1E 7F
^^ ^^ ^^^^^^^^^^^ ^^^^^^^^^^^ ^^ ^^ ^^
Bedeutung SOF MID WR ser# WR ser# CMD ? ? ? ? ? ? CRC8 EOF
Einheit BCD (letzte 8) BCD (letzte 8) ?
Beispiel 72220200 72220200 ? 131 1000 178 10
95 72 22 02 00 72 22 02 00 83 00 03 00 83 03 E8 00 B2 00 0A FD 26 1E
^^ ^^^^^^^^^^^ ^^^^^^^^^^^ ^^ ^^
Bedeutung MID WR ser# WR ser# CMD ? ? ? ? ? ? CRC8
Einheit BCD (letzte 8) BCD (letzte 8) ?
Beispiel 72220200 72220200 ? 131 1000 178 10
```
Legend
======
MID: Message-ID. Antworten haben Bit 7 gesetzt,
z.B. Frage 0x15 --> Antwort 0x95.
z.B. Frage 0x07 --> Antwort 0x87.
Für Kommunikation GD <--> NRF
CMD:
**MID**: Message-ID. Antworten haben Bit 7 gesetzt,
```
z.B. Frage 0x15 --> Antwort 0x95.
z.B. Frage 0x07 --> Antwort 0x87.
Für Kommunikation GD <--> NRF
```
**CMD**:
Befehl an den WR hat Bit 7 gesetzt
0x80 "Zeit setzen"
0x81 "Anfrage DC-Daten", erwartete Antwort: 0x01
@ -460,33 +492,41 @@ CMD:
0x01 "Aktuelle DC-Daten"
0x02 "Aktuelle AC-Daten"
SOF: Start-of-Frame 0x7e
EOF: End-of-Frame 0x7f
CRC8: CRC8 mit poly=1 init=0 xor=0, für alle Bytes zwischen SOF und CRC8.
**SOF**: Start-of-Frame 0x7e
**EOF**: End-of-Frame 0x7f
**CRC8**: CRC8 mit poly=1 init=0 xor=0, für alle Bytes zwischen SOF und CRC8.
Beispiel in Python:
```
>>> import crcmod
>>> f = crcmod.mkCrcFun(0x101, initCrc=0, xorOut=0)
>>> payload = bytes((0x95,0x72,0x22,0x02,0x00,0x72,0x22,0x02,0x00,0x83,0x00,0x03,0x00,0x83,0x03,0xE8,0x00,0xB2,0x00,0x0A,0xFD,0x26))
>>> hex(f(payload))
'0x1e'
```
CRC_M: CRC16 wie für "Modbus"-Protokoll, High-Byte gefolgt von Low-Byte
**CRC_M**: CRC16 wie für "Modbus"-Protokoll, High-Byte gefolgt von Low-Byte
Beispiel in Python:
```
>>> import crcmod
>>> f = crcmod.predefined.mkPredefinedCrcFun('modbus')
>>> payload = bytes((0x0B,0x00,0x62,0x2F,0x45,0x96,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00))
>>> hex(f(payload))
'0x3bd6'
```
TIME: Aktuelle (DTU-)Zeit als Unix "time_t" (Sekunden seit 1970-01-01)
**TIME**: Aktuelle (DTU-)Zeit als Unix "time_t" (Sekunden seit 1970-01-01)
Glossar
=======
Glossary
========
**WR**: Wechselrichter (inverter)
**DTU**: Data Terminal Unit (?). Die Hoymiles-Bezeichnung für den Kommunikations-Master.
WR: Wechselrichter (inverter)
DTU: Data Terminal Unit (?). Die Hoymiles-Bezeichnung für den Kommunikations-Master.
BCD: Binary Coded Decimal
**BCD**: Binary Coded Decimal
Notizen
@ -504,8 +544,9 @@ References
- [1]: https://www.mikrocontroller.net/topic/525778 "The post that started the community effort"
- [2]: https://www.mikrocontroller.net "mikrocontroller.net"
- [3]: "Nordic NRF24LE01+ datasheet"
- [3]: https://infocenter.nordicsemi.com/pdf/nRF24LE1_PS_v1.6.pdf "Nordic NRF24LE01+ datasheet"
- [4]: https://nrf24.github.io/RF24 "Optimized high speed nRF24L01+ driver documentation"
- [5]: https://github.com/grindylow/ahoy "AHOY Communications Project"
Revision History