@ -186,28 +186,33 @@ class Inverter { |
|
|
|
if(mDevControlRequest) { |
|
|
|
cb(devControlCmd, true); |
|
|
|
mDevControlRequest = false; |
|
|
|
} else if (IV_MI != ivGen) { |
|
|
|
} else if (IV_MI != ivGen) { // HM / HMS / HMT
|
|
|
|
mGetLossInterval++; |
|
|
|
if((alarmLastId != alarmMesIndex) && (alarmMesIndex != 0)) |
|
|
|
cb(AlarmData, false); // get last alarms
|
|
|
|
else if(0 == getFwVersion()) |
|
|
|
cb(InverterDevInform_All, false); // get firmware version
|
|
|
|
else if(0 == getHwVersion()) |
|
|
|
cb(InverterDevInform_Simple, false); // get hardware version
|
|
|
|
else if(actPowerLimit == 0xffff) |
|
|
|
cb(SystemConfigPara, false); // power limit info
|
|
|
|
else if(InitDataState != devControlCmd) { |
|
|
|
cb(devControlCmd, false); // custom command which was received by API
|
|
|
|
devControlCmd = InitDataState; |
|
|
|
mGetLossInterval = 1; |
|
|
|
} else if((0 == mGridLen) && generalConfig->readGrid) { // read grid profile
|
|
|
|
cb(GridOnProFilePara, false); |
|
|
|
} else if (mGetLossInterval > AHOY_GET_LOSS_INTERVAL) { // get loss rate
|
|
|
|
mGetLossInterval = 1; |
|
|
|
cb(GetLossRate, false); |
|
|
|
} else |
|
|
|
if(mNextLive) |
|
|
|
cb(RealTimeRunData_Debug, false); // get live data
|
|
|
|
} else { |
|
|
|
else { |
|
|
|
mNextLive = true; |
|
|
|
if(actPowerLimit == 0xffff) |
|
|
|
cb(SystemConfigPara, false); // power limit info
|
|
|
|
else if(InitDataState != devControlCmd) { |
|
|
|
cb(devControlCmd, false); // custom command which was received by API
|
|
|
|
devControlCmd = InitDataState; |
|
|
|
mGetLossInterval = 1; |
|
|
|
} else if((alarmLastId != alarmMesIndex) && (alarmMesIndex != 0)) |
|
|
|
cb(AlarmData, false); // get last alarms
|
|
|
|
else if(0 == getFwVersion()) |
|
|
|
cb(InverterDevInform_All, false); // get firmware version
|
|
|
|
else if(0 == getHwVersion()) |
|
|
|
cb(InverterDevInform_Simple, false); // get hardware version
|
|
|
|
else if((0 == mGridLen) && generalConfig->readGrid) { // read grid profile
|
|
|
|
cb(GridOnProFilePara, false); |
|
|
|
} else if (mGetLossInterval > AHOY_GET_LOSS_INTERVAL) { // get loss rate
|
|
|
|
mGetLossInterval = 1; |
|
|
|
cb(GetLossRate, false); |
|
|
|
} else |
|
|
|
cb(RealTimeRunData_Debug, false); // get live data
|
|
|
|
} |
|
|
|
} else { // MI
|
|
|
|
if(0 == getFwVersion()) |
|
|
|
cb(0x0f, false); // get firmware version; for MI, this makes part of polling the device software and hardware version number
|
|
|
|
else { |
|
|
@ -319,10 +324,10 @@ class Inverter { |
|
|
|
rec->record[pos] = (REC_TYP)(val); |
|
|
|
} |
|
|
|
} |
|
|
|
rec->mqttSentStatus = MqttSentStatus::NEW_DATA; |
|
|
|
} |
|
|
|
|
|
|
|
if(rec == &recordMeas) { |
|
|
|
mNextLive = false; // live data received
|
|
|
|
DPRINTLN(DBG_VERBOSE, "add real time"); |
|
|
|
// get last alarm message index and save it in the inverter object
|
|
|
|
if (getPosByChFld(0, FLD_EVT, rec) == pos) { |
|
|
@ -832,6 +837,7 @@ class Inverter { |
|
|
|
uint16_t mIvRxCnt = 0; |
|
|
|
uint16_t mIvTxCnt = 0; |
|
|
|
uint8_t mAlarmNxtWrPos = 0; // indicates the position in array (rolling buffer)
|
|
|
|
bool mNextLive = true; // first read live data after booting up then version etc.
|
|
|
|
|
|
|
|
public: |
|
|
|
uint16_t mDtuRxCnt = 0; |
|
|
|