					@ -183,11 +183,20 @@ def on_receive(p): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					        j = json.dumps(d) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					        mqtt_client.publish(f'ahoy/{src}/{name}', j) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					        if d['cmd']==2: | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/{name}/p_W', d['p_W']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter/0/voltage', d['u_V']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter/0/power', d['p_W']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter/0/total', d['wtot1_Wh']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/frequency', d['f_Hz']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					        if d['cmd']==1: | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/{name}/p1_W', d['p1_W']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/{name}/p2_W', d['p2_W']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/{name}/p_W', d['p1_W']+d['p2_W']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter-dc/0/power', d['p1_W']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter-dc/0/voltage', d['u1_V']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter-dc/0/current', d['i1_A']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter-dc/1/power', d['p2_W']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter-dc/1/voltage', d['u2_V']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/emeter-dc/1/current', d['i2_A']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					        if d['cmd']==131: | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					            mqtt_client.publish(f'ahoy/{src}/temperature', d['t_C']) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				
					def main_loop(): | 
				
			
			
		
	
	
		
			
				
					| 
						
							
								
							
						
						
						
					 | 
				
				 | 
				
					
  |