* fix display of hidden SSID checkbox
* changed yield correction data type to `double`, now decimal places are supported
* corrected name of 0.91" display in settings
* attempt to fix MqTT zero values only if setting is there #980, #957
* made AP password configurable #951
* added option to start without time-sync, eg. for AP-only-mode #951
* merge PR #876, check JSON settings during read for existance
* **NOTE:** incompatible change: renamed `led_high_active` to `act_high`, maybe setting must be changed after update
* restructure serial debug output (partly)
+ MI - more code review
* fix debug output for power control cmds
* MI - limitation commands answered
* Debug - add more macros and texts
Might as well help for https://github.com/lumapu/ahoy/pull/478
Unfortunately, this atm doesn't really lower used flash memory
* MI - limit command
- now seems to work for MI-600 (to be verified)
- debug - more use of macros (wrt. to real effect see last remark)
webserial minor overflow fix#660
web `index.html` improve version information #701
fix MQTT sets power limit to zero (0) #692
changed `reset at midnight` with timezone #697
added part of mac address to MQTT client ID to seperate multiple ESPs in same network
added dictionary for MQTT to reduce heap-fragmentation
removed `last Alarm` from Live view, because it showed always the same alarm - will change in future
reenabled FlashStringHelper because of lacking RAM
complete rewrite of monochrome display class, thx to @dAjaY85 -> displays are now configurable in setup
improved `isAvailable`, checkes all record structs, inverter becomes available more early because version is check first
fix tickers were not set if NTP is not available
disabled annoying `FlashStringHelper` it gives randomly Expeptions during development, feels more stable since then
moved erase button to the bottom in settings, not nice but more functional
split `tx_count` to `tx_cnt` and `retransmits` in `system.html`
fix mqtt retransmit IP address #602
added debug infos for `scheduler` (web -> `/debug` as trigger prints list of tickers to serial console)
fix Prometheus and JSON endpoints (`config_override.h`) #561
publish MQTT with fixed interval even if inverter is not available #542
added JSON settings upload. NOTE: settings JSON download changed, so only settings should be uploaded starting from version `0.5.70` #551
MQTT topic and inverter name have more allowed characters: `[A-Za-z0-9./#$%&=+_-]+`, thx: @Mo Demman
improved potential issue with `checkTicker`, thx @cbscpe
MQTT option for reset values on midnight / not avail / communication stop #539
small fix in `tickIVCommunication` #534
add `YieldTotal` correction, eg. to have the option to zero at year start #512
fix Prometheus and JSON endpoints (`config_override.h`) #561
publish MQTT with fixed interval even if inverter is not available #542
added JSON settings upload. NOTE: settings JSON download changed, so only settings should be uploaded starting from version `0.5.70` #551
MQTT topic and inverter name have more allowed characters: `[A-Za-z0-9./#$%&=+_-]+`, thx: @Mo Demman
improved potential issue with `checkTicker`, thx @cbscpe
MQTT option for reset values on midnight / not avail / communication stop #539
small fix in `tickIVCommunication` #534
add `YieldTotal` correction, eg. to have the option to zero at year start #512
added icons to index.html, added wifi-strength symbol on each page
moved packet stats and sun to system.html
refactored communication offset (adjustable in minutes now)
included #483 improvements
fix#468 last_success MQTT
fix#468 update available status at sunset
fix#447 reorderd enqueue commands to not have same payload length in a row
added ssd1306 and nokia display to build script
-> now Ahoy opens an AP during boot. This will be closed once a station WiFi connection is established
improved NTP after boot, will be synced immediately after successful WiFi connection
removed wrong "inverter type can't be detected!" messages
repaired NTP and static IP #459
MQTT status about availability and produce are retain messages now