Christian Ehrlicher
f332738ceb
RPI: properly catch exception when crc8 check failed
2 years ago
Christian Ehrlicher
fb6250a109
RPI: Request alarm when alarm id changes
2 years ago
Christian Ehrlicher
de90c19eb3
RPI: add handling for InverterDevInform_All message, handle
RealTimeRunData_Reality similar to RealTimeRunData_Debug
2 years ago
Christian Ehrlicher
73a0397107
RPI: be able to handle more than one inverter with the volkszaehler
plugin
2 years ago
Christian Ehrlicher
c6fb43c4ef
RPI: don't throw exception when no valid frame was received
2 years ago
Christian Ehrlicher
ddbb35eff3
RPI: use a requests seesion for the volkszaehler plugin to be able to
use hhtp keep-alive functionality. Print debug-output only when debug
is enabled
2 years ago
Christian Ehrlicher
6753be8871
Take timestamp from response instead local time
2 years ago
Christian Ehrlicher
5f6b175742
Add comment about missing python modules, move section about ahoy
example config before the 'example run' section.
2 years ago
Christian Ehrlicher
82f1562129
Initial plugin to directly send the values from the inverter to the volkszaehler middleware
2 years ago
ngt-github
616e889e94
Added options for TLS usage for MQTT client and insecure certificate handling
2 years ago
stefan123t
7131ea5c7d
fix line end comments
fix line end comments in tools/rpi/hoymiles/decoders/__init__.py
2 years ago
stefan123t
836dc1526b
Commented Error-Codes with Hex-Equivalents
Commented Error-Codes with Hex-Equivalents
3 years ago
DanielR92
121ce7cbe7
Update __init__.py (short one line)
Use the function 'hexify_payload()' in other lines
3 years ago
stefan123t
d876fe841e
added pyRF24 build instructions from mslookup
3 years ago
Jan-Jonas Sämann
044cf316b5
Decode 80 02 as EventsResponse
Data also looks like some sort of table
3 years ago
Jan-Jonas Sämann
6b47291ac1
Add payload debug function print_table_unpack
Helps recognize values in unknown payloads by decoding data from payload
with different offsets, data types and print results as aligned table
Enhances DebugDecodeAny class
3 years ago
Jan-Jonas Sämann
391fec99d2
Pypackage fix interval sleep time
3 years ago
Jan-Jonas Sämann
4e709254c7
pypackage add event log entry count for 1161
3 years ago
Jan-Jonas Sämann
34f6f9363d
pypackage typo
3 years ago
Jan-Jonas Sämann
d5252866f8
pypackage add txpower min, high
Now txpower can be one of min, low, high, max
3 years ago
Jan-Jonas Sämann
88e9de42b8
pypackage add powerfactor where possible
3 years ago
Jan-Jonas Sämann
68cb8a59d9
Pypackage Disable retransmit in log parse mode
Disable retransmit if InverterTransaction is invoked without an actual
radio attached.
3 years ago
Jan-Jonas Sämann
5935e0dabe
Update pypackage set txpower per nrf/inverter
Add config parameter `txpower` in inverters- and nrf context.
This enables overriding txpower default RF24_PA_MAX, in some cases
inverters require RF24_PA_LOW. For larger setups, txpower can be set per
inverter to be able to query a far away (max) and a near by (low) one from within
one instance.
Valid values can be:
* `txpower: 'max'` (corresponds to RF24_PA_MAX, default)
* `txpower: 'low'` (corresponds to RF24_PA_LOW)
3 years ago
Jan-Jonas Sämann
93b3f02b24
Add pypackage retransmit last frame
Mentioned in #30 by @stefan123t
3 years ago
lumapu
8238e90903
* fix #38 current assignment for 4-channel inverters
* added last received timestamp in /hoymiles livedata web page #47
* improved style.css
* improved NTP as described in #46
3 years ago
Jan-Jonas Sämann
e473583a55
Change alarm code 2
Seems that alarm code 2 appears on failed commands
3 years ago
Jan-Jonas Sämann
e4eebb67e4
Improve python code quality
Mostly fix naming convetion, add descriptions. Cleanup code, left behind
from tinkering.
3 years ago
Jan-Jonas Sämann
2934c23688
Update UnknownResponse decoder
3 years ago
Jan-Jonas Sämann
5101b22ff7
Provide Influx2 output plugin
Allready thougt about it earlier and requested in #29
3 years ago
Jan-Jonas Sämann
7415139038
Provide rx time in response
3 years ago
Jan-Jonas Sämann
e5b427f4f2
Provice decoders super class to ensure properties
3 years ago
Jan-Jonas Sämann
532168e1eb
Allow disable mqtt
3 years ago
Jan-Jonas Sämann
0f52c62b3f
Setup NRF send/receive pipes
Fixes no response from WR
3 years ago
Jan-Jonas Sämann
3aff763e8f
WIP: Partially decode event log 0x11 and 0x12
3 years ago
Jan-Jonas Sämann
d408264521
Adds documentation to python-hoymiles module
3 years ago
Jan-Jonas Sämann
38346abde2
Update python decoders improves protocol analysis
3 years ago
Jan-Jonas Sämann
d27f0c1148
Integrate ahoy.py into hoymiles module
Finally get rid of ahoy.py and integrate functionallity into the module
itself. Prepares for pipelines, adding pip installer or debian packaging.
Improve configuration adds commandline switches for:
* `--verbose, enabling verbose logging
* `--log-transactions`, outbut all rf raw data
Improve loop, now runs all queued commands per inverter within interval.
Skip sleep when interval is allready due.
3 years ago
Jan-Jonas Sämann
6627eeb931
Update channel hop list
remove channel 9 and 11 because there was never seen a single frame
received
3 years ago
Jan-Jonas Sämann
1ef4507e8f
Update 1161-Series decoders
Fixes missing HM1200 decoder
3 years ago
Jan-Jonas Sämann
ff615dba8b
Pull-in diff from franz supports 1121-Series
Source
https://www.mikrocontroller.net/topic/525778#7058357
3 years ago
Jan-Jonas Sämann
3b54b58567
Update Decodes, group decoders by inverter serial
Seems to be that we can not exactly determine the actual model by
looking at the serial. What we seemingly can guess is how many MPPT and
Phases a range of serials have.
Some Group-Based decoders should be compatible across the group.
A group is now named by the lowest model
* 1121: HM300 1 MPPT, 1 Phase
* 1141: HM600 2 MPPT, 1 Phase
* 1161: HM1200 4 MPPT, 1 Phase
3 years ago
Thomas Basler
31aba4d722
Fixed divider for AC Current
3 years ago
Thomas Basler
767e1c5ee9
Fixed Power assignment for DC Port 1
3 years ago
Jan-Jonas Sämann
976991df46
Remove debug script test.py
3 years ago
Jan-Jonas Sämann
ef67cbe26e
Add python requirement PyYAML
3 years ago
Jan-Jonas Sämann
0ee867993c
MQTT payload injection and default unknown decoder
Adds the ability to directly inject payloads to be sent to the inverter.
Fixes application crash at missing decoder by adding default decoding.
All unknown payloads are now printed as long- and short-lists for faster
protocol analysis
3 years ago
Thomas Basler
e8ad778918
Fixed total production for string 3
3 years ago
Thomas Basler
eb2608b77d
Fixed syntax errors
3 years ago
Thomas Basler
39e253bc28
Added parser for HM-1500
3 years ago
Jan-Jonas Sämann
a1cfaf5918
Change default mqtt prefix to hoymiles/serial
3 years ago