mqtt: sensor: - state_topic: "inverter/uptime" icon: mdi:clock-start name: "Inverter Uptime" unique_id: "ahoy_ch0_uptime" value_template: > {% set time = value|int %} {% set minutes = ((time % 3600) / 60) | int %} {% set hours = ((time % 86400) / 3600) | int %} {% set days = (time / 86400) | int %} {%- if time < 60 -%} Less than a minute {%- else -%} {%- if days > 0 -%} {%- if days == 1 -%} 1 day {%- else -%} {{ days }} days {%- endif -%} {%- endif -%} {%- if hours > 0 -%} {%- if days > 0 -%} {{ ', ' }} {%- endif -%} {%- if hours == 1 -%} 1 hour {%- else -%} {{ hours }} hours {%- endif -%} {%- endif -%} {%- if minutes > 0 -%} {%- if days > 0 or hours > 0 -%} {{ ', ' }} {%- endif -%} {%- if minutes == 1 -%} 1 minute {%- else -%} {{ minutes }} minutes {%- endif -%} {%- endif -%} {%- endif -%} - state_topic: "inverter/GardenShed/ch0/Efficiency" icon: "mdi:trending-up" name: "Inverter Efficiency" unique_id: "ahoy_ch0_efficiency" unit_of_measurement: "%" - state_topic: "inverter/GardenShed/ch0/P_DC" device_class: "power" name: "Inverter DC Power" unique_id: "ahoy_ch0_p_dc" unit_of_measurement: "W" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/YieldTotal" device_class: "energy" icon: "mdi:lightning-bolt-outline" name: "Inverter Total Yield" unique_id: "ahoy_ch0_yield_total" unit_of_measurement: "kWh" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/YieldDay" device_class: "energy" name: "Inverter Day Yield" unique_id: "ahoy_ch0_yield_day" unit_of_measurement: "Wh" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/ALARM_MES_ID" name: "Inverter Alarm Message ID" unique_id: "ahoy_ch0_alarm_mes_id" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/LastAlarmCode" icon: "mdi:message-alert" name: "Inverter Last Alarm" unique_id: "ahoy_ch0_last_alarm" value_template: > {% set value = value|round(0) %} {% set mapper = { 0: "Nothing", 1: 'Inverter start', 2: 'DTU command failed', 121: 'Over temperature protection', 125: 'Grid configuration parameter error', 126: 'Software error code 126', 127: 'Firmware error', 128: 'Software error code 128', 129: 'Software error code 129', 130: 'Offline', 141: 'Grid overvoltage', 142: 'Average grid overvoltage', 143: 'Grid undervoltage', 144: 'Grid overfrequency', 145: 'Grid underfrequency', 146: 'Rapid grid frequency change', 147: 'Power grid outage', 148: 'Grid disconnection', 149: 'Island detected', 205: 'Input port 1 & 2 overvoltage', 206: 'Input port 3 & 4 overvoltage', 207: 'Input port 1 & 2 undervoltage', 208: 'Input port 3 & 4 undervoltage', 209: 'Port 1 no input', 210: 'Port 2 no input', 211: 'Port 3 no input', 212: 'Port 4 no input', 213: 'PV-1 & PV-2 abnormal wiring', 214: 'PV-3 & PV-4 abnormal wiring', 215: 'PV-1 Input overvoltage', 216: 'PV-1 Input undervoltage', 217: 'PV-2 Input overvoltage', 218: 'PV-2 Input undervoltage', 219: 'PV-3 Input overvoltage', 220: 'PV-3 Input undervoltage', 221: 'PV-4 Input overvoltage', 222: 'PV-4 Input undervoltage', 301: 'Hardware error code 301', 302: 'Hardware error code 302', 303: 'Hardware error code 303', 304: 'Hardware error code 304', 305: 'Hardware error code 305', 306: 'Hardware error code 306', 307: 'Hardware error code 307', 308: 'Hardware error code 308', 309: 'Hardware error code 309', 310: 'Hardware error code 310', 311: 'Hardware error code 311', 312: 'Hardware error code 312', 313: 'Hardware error code 313', 314: 'Hardware error code 314', 5041: 'Error code-04 Port 1', 5042: 'Error code-04 Port 2', 5043: 'Error code-04 Port 3', 5044: 'Error code-04 Port 4', 5051: 'PV Input 1 Overvoltage/Undervoltage', 5052: 'PV Input 2 Overvoltage/Undervoltage', 5053: 'PV Input 3 Overvoltage/Undervoltage', 5054: 'PV Input 4 Overvoltage/Undervoltage', 5060: 'Abnormal bias', 5070: 'Over temperature protection', 5080: 'Grid Overvoltage/Undervoltage', 5090: 'Grid Overfrequency/Underfrequency', 5100: 'Island detected', 5120: 'EEPROM reading and writing error', 5150: '10 min value grid overvoltage', 5200: 'Firmware error', 8310: 'Shut down', 9000: 'Microinverter is suspected of being stolen' } %} {{ mapper[value] if value in mapper else "value is unknon" }} - state_topic: "inverter/GardenShed/ch0/Temp" device_class: "temperature" name: "Inverter Temperature" unique_id: "ahoy_ch0_temp" unit_of_measurement: "°C" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/Freq" device_class: "frequency" name: "Inverter Frequency" unique_id: "ahoy_ch0_freq" unit_of_measurement: "Hz" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/P_ACr" device_class: "power" name: "Inverter AC Reactive Power" unique_id: "ahoy_ch0_p_acr" unit_of_measurement: "VA" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/P_AC" device_class: "power" name: "Inverter AC Power" unique_id: "ahoy_ch0_p_ac" unit_of_measurement: "W" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/I_AC" device_class: "current" name: "Inverter AC Current" unique_id: "ahoy_ch0_i_ac" unit_of_measurement: "A" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/U_AC" device_class: "voltage" icon: "mdi:current-ac" name: "Inverter AC Voltage" unique_id: "ahoy_ch0_u_ac" unit_of_measurement: "V" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch0/Pct" device_class: "power_factor" name: "Inverter Power Factor" unique_id: "ahoy_ch0_pct" - state_topic: "inverter/GardenShed/ch0/FWVersion" icon: "mdi:numeric" name: "Inverter Firmware Version" unique_id: "ahoy_ch0_fw_version" value_template: > {{ value | round(0) | regex_replace('([0-9]+)([0-9]{2})([0-9]{2})$', '\\1.\\2.\\3') }} - state_topic: "inverter/GardenShed/ch0/FWBuildYear" icon: "mdi:calendar-blank" name: "Inverter Firmware build year" unique_id: "ahoy_ch0_fw_builid_year" value_template: > {{value|round(0)}} - state_topic: "inverter/GardenShed/ch0/FWBuildMonthDay" icon: "mdi:calendar-clock" name: "Inverter Firmware build month and day" unique_id: "ahoy_ch0_fw_builid_month_day" - state_topic: "inverter/GardenShed/ch0/HWPartId" icon: "mdi:identifier" name: "Inverter Hardware ID" unique_id: "ahoy_ch0_hw_part_id" value_template: > {{value|round(0)}} - state_topic: "inverter/GardenShed/ch0/PowerLimit" icon: "mdi:speedometer" name: "Inverter Power Limit" unique_id: "ahoy_ch0_power_limit" unit_of_measurement: "%" value_template: > {{value|round(0)}} - state_topic: "inverter/GardenShed/ch1/Irradiation" icon: "mdi:weather-partly-cloudy" name: "Inverter Channel 1 Irradiation" unique_id: "ahoy_ch1_irradiation" unit_of_measurement: "%" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch1/YieldTotal" device_class: "energy" icon: "mdi:lightning-bolt-outline" name: "Inverter Channel 1 Total Yield" unique_id: "ahoy_ch1_yield_total" unit_of_measurement: "kWh" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch1/YieldDay" device_class: "energy" name: "Inverter Channel 1 Day Yield" unique_id: "ahoy_ch1_yield_day" unit_of_measurement: "Wh" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch1/P_DC" device_class: "power" name: "Inverter Channel 1 AC Power" unique_id: "ahoy_ch1_p_dc" unit_of_measurement: "W" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch1/I_DC" device_class: "current" icon: "mdi:current-dc" name: "Inverter Channel 1 AC Current" unique_id: "ahoy_ch1_i_dc" unit_of_measurement: "A" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch1/U_DC" device_class: "voltage" icon: "mdi:current-dc" name: "Inverter Channel 1 AC Voltage" unique_id: "ahoy_ch1_u_dc" unit_of_measurement: "V" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch2/Irradiation" icon: "mdi:weather-partly-cloudy" name: "Inverter Channel 2 Irradiation" unique_id: "ahoy_ch2_irradiation" unit_of_measurement: "%" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch2/YieldTotal" device_class: "energy" icon: "mdi:lightning-bolt-outline" name: "Inverter Channel 2 Total Yield" unique_id: "ahoy_ch2_yield_total" unit_of_measurement: "kWh" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch2/YieldDay" device_class: "energy" name: "Inverter Channel 2 Day Yield" unique_id: "ahoy_ch2_yield_day" unit_of_measurement: "Wh" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch2/P_DC" device_class: "power" name: "Inverter Channel 2 AC Power" unique_id: "ahoy_ch2_p_dc" unit_of_measurement: "W" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch2/I_DC" device_class: "current" icon: "mdi:current-dc" name: "Inverter Channel 2 AC Current" unique_id: "ahoy_ch2_i_dc" unit_of_measurement: "A" value_template: > {{value|round(3)}} - state_topic: "inverter/GardenShed/ch2/U_DC" device_class: "voltage" icon: "mdi:current-dc" name: "Inverter Channel 2 AC Voltage" unique_id: "ahoy_ch2_u_dc" unit_of_measurement: "V" value_template: > {{value|round(3)}}