#!/usr/bin/env python3
|
|
|
|
import socket
|
|
from datetime import datetime, timezone
|
|
from hoymiles.decoders import StatusResponse
|
|
|
|
try:
|
|
from influxdb_client import InfluxDBClient
|
|
except ModuleNotFoundError:
|
|
pass
|
|
|
|
class OutputPluginFactory:
|
|
def __init__(self, **params):
|
|
"""Initialize output plugin"""
|
|
|
|
self.inverter_ser = params.get('inverter_ser', 0)
|
|
|
|
def store_status(self, data):
|
|
raise NotImplementedError('The current output plugin does not implement store_status')
|
|
|
|
class InfluxOutputPlugin(OutputPluginFactory):
|
|
def __init__(self, url, token, **params):
|
|
super().__init__(**params)
|
|
|
|
self._bucket = params.get('bucket', 'hoymiles/autogen')
|
|
self._org = params.get('org', '')
|
|
self._measurement = params.get('measurement',
|
|
f'inverter,host={socket.gethostname()}')
|
|
|
|
client = InfluxDBClient(url, token, bucket=self._bucket)
|
|
self.api = client.write_api()
|
|
|
|
def store_status(self, response):
|
|
"""
|
|
Publish StatusResponse object
|
|
|
|
:param influxdb.InfluxDBClient influx_client: A connected instance to Influx database
|
|
:param str inverter_ser: inverter serial
|
|
:param hoymiles.StatusResponse data: decoded inverter StatusResponse
|
|
:type response: hoymiles.StatusResponse
|
|
:param measurement: Influx measurement name
|
|
:type measurement: str
|
|
"""
|
|
|
|
if not isinstance(response, StatusResponse):
|
|
raise RuntimeError('Data needs to be instance of StatusResponse')
|
|
|
|
data = response.__dict__()
|
|
|
|
measurement = self._measurement + f',location={data["inverter_ser"]}'
|
|
|
|
data_stack = []
|
|
|
|
time_rx = datetime.now()
|
|
if 'time' in data and isinstance(data['time'], datetime):
|
|
time_rx = data['time']
|
|
|
|
# InfluxDB uses UTC
|
|
utctime = datetime.fromtimestamp(time_rx.timestamp(), tz=timezone.utc)
|
|
|
|
# InfluxDB requires nanoseconds
|
|
ctime = int(utctime.timestamp() * 1e9)
|
|
|
|
# AC Data
|
|
phase_id = 0
|
|
for phase in data['phases']:
|
|
data_stack.append(f'{measurement},phase={phase_id},type=power value={phase["power"]} {ctime}')
|
|
data_stack.append(f'{measurement},phase={phase_id},type=voltage value={phase["voltage"]} {ctime}')
|
|
data_stack.append(f'{measurement},phase={phase_id},type=current value={phase["current"]} {ctime}')
|
|
phase_id = phase_id + 1
|
|
|
|
# DC Data
|
|
string_id = 0
|
|
for string in data['strings']:
|
|
data_stack.append(f'{measurement},string={string_id},type=total value={string["energy_total"]/1000:.4f} {ctime}')
|
|
data_stack.append(f'{measurement},string={string_id},type=power value={string["power"]:.2f} {ctime}')
|
|
data_stack.append(f'{measurement},string={string_id},type=voltage value={string["voltage"]:.3f} {ctime}')
|
|
data_stack.append(f'{measurement},string={string_id},type=current value={string["current"]:3f} {ctime}')
|
|
string_id = string_id + 1
|
|
# Global
|
|
data_stack.append(f'{measurement},type=frequency value={data["frequency"]:.3f} {ctime}')
|
|
data_stack.append(f'{measurement},type=temperature value={data["temperature"]:.2f} {ctime}')
|
|
|
|
self.api.write(self._bucket, self._org, data_stack)
|
|
|
|
try:
|
|
import paho.mqtt.client
|
|
except ModuleNotFoundError:
|
|
pass
|
|
|
|
class MqttOutputPlugin(OutputPluginFactory):
|
|
def __init__(self, *args, **params):
|
|
super().__init__(*args, **params)
|
|
|
|
mqtt_client = paho.mqtt.client.Client()
|
|
mqtt_client.username_pw_set(params.get('user', None), params.get('password', None))
|
|
mqtt_client.connect(params.get('host', '127.0.0.1'), params.get('port', 1883))
|
|
mqtt_client.loop_start()
|
|
|
|
self.client = mqtt_client
|
|
|
|
def store_status(self, response, **params):
|
|
"""
|
|
Publish StatusResponse object
|
|
|
|
:param paho.mqtt.client.Client broker: mqtt-client instance
|
|
:param str inverter_ser: inverter serial
|
|
:param hoymiles.StatusResponse data: decoded inverter StatusResponse
|
|
:param topic: custom mqtt topic prefix (default: hoymiles/{inverter_ser})
|
|
:type topic: str
|
|
"""
|
|
|
|
if not isinstance(response, StatusResponse):
|
|
raise RuntimeError('Data needs to be instance of StatusResponse')
|
|
|
|
data = response.__dict__()
|
|
|
|
topic = params.get('topic', f'hoymiles/{inverter_ser}')
|
|
|
|
# AC Data
|
|
phase_id = 0
|
|
for phase in data['phases']:
|
|
self.mqtt_client.publish(f'{topic}/emeter/{phase_id}/power', phase['power'])
|
|
self.mqtt_client.publish(f'{topic}/emeter/{phase_id}/voltage', phase['voltage'])
|
|
self.mqtt_client.publish(f'{topic}/emeter/{phase_id}/current', phase['current'])
|
|
phase_id = phase_id + 1
|
|
|
|
# DC Data
|
|
string_id = 0
|
|
for string in data['strings']:
|
|
self.mqtt_client.publish(f'{topic}/emeter-dc/{string_id}/total', string['energy_total']/1000)
|
|
self.mqtt_client.publish(f'{topic}/emeter-dc/{string_id}/power', string['power'])
|
|
self.mqtt_client.publish(f'{topic}/emeter-dc/{string_id}/voltage', string['voltage'])
|
|
self.mqtt_client.publish(f'{topic}/emeter-dc/{string_id}/current', string['current'])
|
|
string_id = string_id + 1
|
|
# Global
|
|
self.mqtt_client.publish(f'{topic}/frequency', data['frequency'])
|
|
self.mqtt_client.publish(f'{topic}/temperature', data['temperature'])
|
|
|