@ -594,14 +594,40 @@ class Inverter { |
|
|
|
static String getAlarmStr(uint16_t alarmCode) { |
|
|
|
switch (alarmCode) { // breaks are intentionally missing!
|
|
|
|
case 1: return String(F("Inverter start")); |
|
|
|
case 2: return String(F("DTU command failed")); |
|
|
|
case 73: return String(F("Temperature >80°C")); // https://github.com/tbnobody/OpenDTU/discussions/590#discussioncomment-6049750
|
|
|
|
case 2: return String(F("Time calibration")); |
|
|
|
case 3: return String(F("EEPROM reading and writing error during operation")); |
|
|
|
case 4: return String(F("Offline")); |
|
|
|
case 11: return String(F("Grid voltage surge")); |
|
|
|
case 12: return String(F("Grid voltage sharp drop")); |
|
|
|
case 13: return String(F("Grid frequency mutation")); |
|
|
|
case 14: return String(F("Grid phase mutation")); |
|
|
|
case 15: return String(F("Grid transient fluctuation")); |
|
|
|
case 36: return String(F("INV overvoltage or overcurrent")); |
|
|
|
case 46: return String(F("FB overvoltage")); |
|
|
|
case 47: return String(F("FB overcurrent")); |
|
|
|
case 48: return String(F("FB clamp overvoltage")); |
|
|
|
case 49: return String(F("FB clamp overvoltage")); |
|
|
|
case 61: return String(F("Calibration parameter error")); |
|
|
|
case 62: return String(F("System configuration parameter error")); |
|
|
|
case 63: return String(F("Abnormal power generation data")); |
|
|
|
|
|
|
|
case 71: return String(F("Grid overvoltage load reduction (VW) function enable")); |
|
|
|
case 72: return String(F("Power grid over-frequency load reduction (FW) function enable")); |
|
|
|
case 73: return String(F("Over-temperature load reduction (TW) function enable")); |
|
|
|
|
|
|
|
case 95: return String(F("PV-1: Module in suspected shadow")); |
|
|
|
case 96: return String(F("PV-2: Module in suspected shadow")); |
|
|
|
case 97: return String(F("PV-3: Module in suspected shadow")); |
|
|
|
case 98: return String(F("PV-4: Module in suspected shadow")); |
|
|
|
|
|
|
|
case 121: return String(F("Over temperature protection")); |
|
|
|
case 122: return String(F("Microinverter is suspected of being stolen")); |
|
|
|
case 123: return String(F("Locked by remote control")); |
|
|
|
case 124: return String(F("Shut down by remote control")); |
|
|
|
case 125: return String(F("Grid configuration parameter error")); |
|
|
|
case 126: return String(F("Software error code 126")); |
|
|
|
case 126: return String(F("EEPROM reading and writing error")); |
|
|
|
case 127: return String(F("Firmware error")); |
|
|
|
case 128: return String(F("Software error code 128")); |
|
|
|
case 128: return String(F("Hardware configuration error")); |
|
|
|
case 129: return String(F("Abnormal bias")); |
|
|
|
case 130: return String(F("Offline")); |
|
|
|
case 141: return String(F("Grid: Grid overvoltage")); |
|
|
@ -613,7 +639,12 @@ class Inverter { |
|
|
|
case 147: return String(F("Grid: Power grid outage")); |
|
|
|
case 148: return String(F("Grid: Grid disconnection")); |
|
|
|
case 149: return String(F("Grid: Island detected")); |
|
|
|
|
|
|
|
case 150: return String(F("DCI exceeded")); |
|
|
|
|
|
|
|
case 171: return String(F("Grid: Abnormal phase difference between phase to phase")); |
|
|
|
case 181: return String(F("Abnormal insulation impedance")); |
|
|
|
case 182: return String(F("Abnormal grounding")); |
|
|
|
case 205: return String(F("MPPT-A: Input overvoltage")); |
|
|
|
case 206: return String(F("MPPT-B: Input overvoltage")); |
|
|
|
case 207: return String(F("MPPT-A: Input undervoltage")); |
|
|
@ -632,24 +663,33 @@ class Inverter { |
|
|
|
case 220: return String(F("PV-3: Input undervoltage")); |
|
|
|
case 221: return String(F("PV-4: Input overvoltage")); |
|
|
|
case 222: return String(F("PV-4: Input undervoltage")); |
|
|
|
case 301: return String(F("Hardware error code 301")); |
|
|
|
case 302: return String(F("Hardware error code 302")); |
|
|
|
case 303: return String(F("Hardware error code 303")); |
|
|
|
case 304: return String(F("Hardware error code 304")); |
|
|
|
case 305: return String(F("Hardware error code 305")); |
|
|
|
case 306: return String(F("Hardware error code 306")); |
|
|
|
case 307: return String(F("Hardware error code 307")); |
|
|
|
case 308: return String(F("Hardware error code 308")); |
|
|
|
|
|
|
|
case 301: return String(F("FB short circuit failure")); |
|
|
|
case 302: return String(F("FB short circuit failure")); |
|
|
|
case 303: return String(F("FB overcurrent protection failure")); |
|
|
|
case 304: return String(F("FB overcurrent protection failure")); |
|
|
|
case 305: return String(F("FB clamp circuit failure")); |
|
|
|
case 306: return String(F("FB clamp circuit failure")); |
|
|
|
case 307: return String(F("INV power device failure")); |
|
|
|
case 308: return String(F("INV overcurrent or overvoltage protection failure")); |
|
|
|
case 309: return String(F("Hardware error code 309")); |
|
|
|
case 310: return String(F("Hardware error code 310")); |
|
|
|
case 311: return String(F("Hardware error code 311")); |
|
|
|
case 312: return String(F("Hardware error code 312")); |
|
|
|
case 313: return String(F("Hardware error code 313")); |
|
|
|
case 314: return String(F("Hardware error code 314")); |
|
|
|
case 5041: return String(F("Error code-04 Port 1")); |
|
|
|
case 5042: return String(F("Error code-04 Port 2")); |
|
|
|
case 5043: return String(F("Error code-04 Port 3")); |
|
|
|
case 5044: return String(F("Error code-04 Port 4")); |
|
|
|
|
|
|
|
case 5011: return String(F("PV-1: MOSFET overcurrent (II)")); |
|
|
|
case 5012: return String(F("PV-2: MOSFET overcurrent (II)")); |
|
|
|
case 5013: return String(F("PV-3: MOSFET overcurrent (II)")); |
|
|
|
case 5014: return String(F("PV-4: MOSFET overcurrent (II)")); |
|
|
|
case 5020: return String(F("H-bridge MOSFET overcurrent or H-bridge overvoltage")); |
|
|
|
|
|
|
|
case 5041: return String(F("PV-1: current overcurrent (II)")); |
|
|
|
case 5042: return String(F("PV-2: current overcurrent (II)")); |
|
|
|
case 5043: return String(F("PV-3: current overcurrent (II)")); |
|
|
|
case 5044: return String(F("PV-4: current overcurrent (II)")); |
|
|
|
|
|
|
|
case 5051: return String(F("PV Input 1 Overvoltage/Undervoltage")); |
|
|
|
case 5052: return String(F("PV Input 2 Overvoltage/Undervoltage")); |
|
|
|
case 5053: return String(F("PV Input 3 Overvoltage/Undervoltage")); |
|
|
@ -659,10 +699,18 @@ class Inverter { |
|
|
|
case 5080: return String(F("Grid Overvoltage/Undervoltage")); |
|
|
|
case 5090: return String(F("Grid Overfrequency/Underfrequency")); |
|
|
|
case 5100: return String(F("Island detected")); |
|
|
|
case 5110: return String(F("GFDI")); |
|
|
|
case 5120: return String(F("EEPROM reading and writing error")); |
|
|
|
case 5141: |
|
|
|
case 5142: |
|
|
|
case 5143: |
|
|
|
case 5144: |
|
|
|
return String(F("FB clamp overvoltage")); |
|
|
|
case 5150: return String(F("10 min value grid overvoltage")); |
|
|
|
case 5160: return String(F("Grid transient fluctuation")); |
|
|
|
case 5200: return String(F("Firmware error")); |
|
|
|
case 8310: return String(F("Shut down")); |
|
|
|
case 8310: return String(F("Shut down by remote control")); |
|
|
|
case 8320: return String(F("Locked by remote control")); |
|
|
|
case 9000: return String(F("Microinverter is suspected of being stolen")); |
|
|
|
default: return String(F("Unknown")); |
|
|
|
} |
|
|
|