Browse Source

Merge branch 'main' into development

pull/168/head
Andreas Schiffler 2 years ago
parent
commit
9efe7cf6ad
  1. 14
      tools/esp8266/User_Manual.md

14
tools/esp8266/User_Manual.md

@ -10,7 +10,7 @@ In the initial case or after click "erase settings" the fields for the inverter
Set at least the serial number and a name for each inverter, check the "reboot after save" and click the "Save" button.
## Active Power Limit via Setup Page
I you leave the field "Active Power Limit" empty during the setup and reboot the ahoy-dtu a value of 65535 will be filled in.
If you leave the field "Active Power Limit" empty during the setup and reboot the ahoy-dtu a value of 65535 will be filled in.
That is the value you have to fill in case you want to operate the inverter without a active power limit.
If the value is 65535 or -1 after another reboot the value will be set automatically to "100" and in the drop-down menu "relative in percent persistent" will be set. Of course you can do this also by your self.
@ -32,12 +32,12 @@ The ahoy-dtu subscribes on the topic <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/# if
To set the absolut active power limit you have four options.
| topic | payload | note |
| --------------------------------------------------------------- | ----------- | -------------------------------------------- |
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11 OR <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/0 | [0..65535] | active power limit in Watt, not persistent |
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/256 | [0...65535] | active power limit in Watt, persistent |
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/1 | [2...100] | active power limit in percent not persistent |
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/257 | [2...100] | active power limit in percent persistent |
| topic | payload | active power limit in | Condition |
| --------------------------------------------------------------- | ----------- | -------------------------------------------- | -------------- |
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11 OR <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/0 | [0..65535] | Watt | not persistent
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/256 | [0...65535] | Watt | persistent
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/1 | [2...100] | % | not persistent
| <CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/11/257 | [2...100] | % | persistent
### Developer Information MQTT Interface
<CHOOSEN_TOPIC_FROM_SETUP>/devcontrol/<INVERTER_ID>/<DevControlCmdType>/<DATA2>

Loading…
Cancel
Save